Not happy, Money back
+31(0)78-6456669 (Available Monday / Friday 9:00-20:00)

Hanna HI97105c Marine Master set

Hanna HI97105c Marine Master Set Measure 6 important parameters with one photometer for your seawater aquarium The HI97105 from Hanna Instruments measures alkalinity, calcium, phosphate, nitrate,...

Hanna HI97105c Marine Master set

Hanna HI97105c Marine Master Set Measure 6 important parameters with one photometer for your seawater aquarium

The HI97105 from Hanna Instruments measures alkalinity, calcium, phosphate, nitrate, nitrite and pH in seawater. This makes it the most versatile, user-friendly and affordable photometer for the aquarium enthusiast!

The compact HI97105 Marine Master benefits from Hanna Instruments' many years of experience as a manufacturer of laboratory instruments for water analysis. The photometer has an advanced optical system that allows accurate and repeatable measurements.
This submersible meter is extremely intuitive, with a help mode that guides you step by step.

HI97105 for seawater

  • pH, Alkalinity, Calcium, Nitrate, Nitrite and Phosphate
  • Advanced optical system with LED
  • Dip-tight
  • User friendly
  • CAL Check
  • Logs last 50 measurements, with tank indication
  • Help mode with step-by-step instructions

This submersible meter is extremely intuitive and easy to use, with a help mode that guides you step by step.

  • CAL Check
  • Advanced optical system with optical filters for high accuracy
  • IP67 housing
  • Logs the last 50 measurements
  • Response timer
  • Battery status indication and automatic shutdown
  • Help mode with step-by-step instructions

The reference system compensates for any drift due to power fluctuations or changes in ambient temperature. With an LED light source, you quickly obtain a stable measurement. A reference detector and a focus lens eliminate any errors caused by the light source or imperfection of the glass cuvette. The relatively long path length of the sample cuvette guarantees accurate measurements, even at low absorbance.

The optical system is sealed from outside dust, dirt and water. The meter uses an exclusive locking system to ensure that the cuvettes are placed in the same position in the holder every time.

CAL Check™

Hanna Instruments' exclusive CAL Check feature provides performance verification and calibration of the meter according to NIST. Our CAL Check standard cuvettes are designed to simulate a specific absorbance value at that wavelength to verify the accuracy of the measurements. The CAL Check display guides the user step-by-step through the validation process and user calibration.

Help function

The built-in help guides you step by step through the measurement process. It includes all steps required for sample preparation, required reagents and quantities.

Stable light source

The internal reference system of these photometers compensates for any drift due to current fluctuations or changes in ambient temperature. With a stable light source, readings are fast and stable between the blank (zero) reading and sample reading.

Intuitive display

This photometer is designed with an illuminated display with virtual keys, a battery status indicator and error messages. The selected parameter and method used are displayed together with the measured value.

Battery status

These meters use three AA batteries that can take approximately 800 measurements. The meter automatically turns off after 15 minutes of inactivity to conserve battery life. An indicator shows the remaining battery life.

Each HI97105c kit comes with:

  • Sample cuvettes and caps (2)
  • 1.5V AA alkaline batteries (3)
  • instruction manual
  • quality certificate
  • carrying case
  • reagent pH seawater, 30 ml
  • reagent alkalinity seawater, 30 ml
  • reagent calcium seawater A, 30 ml
  • reagent calcium seawater B (25 tests)
  • reagent nitrate high range seawater (25 tests)
  • reagent nitrite ultra-low range seawater (25 tests)
  • reagent phosphate ultra-low range seawater (25 tests)
  • 1 ml measuring syringe with tip (2)
  • mini pipette with tip
  • 3 ml Pasteur pipette (2)
  • cuvette cleaning cloth
  • scissors

Used reagent sets:

  • HI758-26 reagent for calcium seawater (25 tests)
  • HI764-25 reagent for nitrite ULR seawater (25 tests)
  • HI772-26 Seawater Alkalinity Reagent (25 tests)
  • HI774-25 Reagent for Phosphate ULR Seawater (25 tests)
  • HI780-25 reagent for pH (100 tests)
  • HI781-25 reagent for nitrate LR seawater (25 tests)
  • HI782-25 reagent for nitrate HR seawater (25 tests
Hanna HI97105c Marine Master set
Hanna HI97105c Marine Master set

Technical specifications

Specification Name Detail
sku HI97105
Alkalinity, Marine Range 0.0 to 20.0 dkH
0 to 357 ppm (ash CaCO3)
Alkalinity, Marine Resolution 0.1 dkH
Alkalinity, Marine Accuracy ±0.3 dKH ±5 % of reading at 25 °C
±5 ppm ±5 % of reading at 25 °C
Alkalinity, Marine Method Colorimetric Method – The reaction causes a distinctive range of colors from yellow to greenish blue to develop
Calcium, Marine Range 200 to 600ppm
Calcium, Marine Resolution 1ppm
Calcium, Marine Accuracy ±6% of reading at 25 °C
Calcium, Marine Method Adaptation of the Zincon Method
Nitrate Range 0.00 to 5.00 ppm (ash NO3¯)
0.0 to 75.0 ppm (ash NO3¯)
Nitrate Resolution 0.01ppm
0.1ppm
Nitrate Accuracy 0 to 200 ppb (ash NO2¯-N)
Nitrate Method Adaptation of the Zincon Method
Colorimetric Method The reaction between nitrate and the reagent causes a pink/violet tint in the sample.
Nitrite, Marine ULR Range 0 to 200 ppb (ash NO2¯-N)
Nitrite, Marine ULR Resolution 1 ppb
Nitrite, Marine ULR Accuracy ±10 ppb ±4 % of reading at 25 °C
Nitrite, Marine ULR Method Adaptation of the EPA Diazotization Method 354.1 – The reaction between nitrite and the reagent causes a pink tint in the sample.
pH Range 6.3 to 8.6 pH
pH Resolution 0.1 pH
pH Accuracy ±0.2 pH of reading at 25 °C
pH Method Colorimetric Adaptation of the Phenol Red Method
Phosphate, LR Range 0.00 to 0.90 ppm
Phosphate, LR Resolution 0.01ppm
Phosphate, LR Accuracy ±0.02 ppm ±5 % of reading at 25 °C
Phosphate, LR Method Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method – The reaction between phosphate and the reagent causes a blue tint in the sample.
light source light emitting diode
Light Detector Silicon photocell
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0nm
Logging 200 readings
power supply 1.5 V AA Alkaline (3 pcs.)
Battery Life > 800 measurements (without backlight)
Auto-off After 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50°C (32 to 122°F); 0 to 100% RH, non‑serviceable
Dimensions 142.5 x 102.5 x 50.5mm (5.6 x 4.0 x 2.0″)
weight 380 g (13.4 oz.); with batteries
Warranty 2 years

Shipment

  • Above € 50,- free delivery in NL & BE
    In stock Ordered before 16:00, shipped today *

Images

Browse products
  • Hanna HI97105c Marine Master set Add to cart
    Not in stock

    Hanna HI97105c Marine Master set

    Delivery time 1-2 weeks
    € 849.99 € 637.49
You have recently viewed the following products.