Hanna HI736-25 Phosphorus ULR Reagents – 25 Tests
Original Hanna HI736-25 replacement reagents for the HI736 Phosphorus Ultra Low Range Checker. The updated reagent kit now consists of two separate powders that are added sequentially during testing. Suitable for 25 complete phosphorus measurements within a range of 0 to 200 µg/L (ppb).
Hanna HI736-25 – Phosphorus ULR Reagents
The Hanna HI736-25 reagent kit is specifically designed for use with the Hanna HI736 Phosphorus Ultra Low Range Checker. These reagents allow accurate measurement of phosphorus concentrations in aquarium water, which is particularly important for marine and reef aquariums containing sensitive corals.
Each kit contains enough reagents for 25 complete tests and is suitable for measuring phosphorus concentrations from 0 to 200 µg/L (ppb).
Updated Reagents – Now Supplied as Two Separate Sachets
Important: Hanna Instruments has changed the composition and packaging of the HI736-25 reagents.
Previously, a single sachet of HI736-0 phosphorus reagent was used for each measurement. The updated version now consists of two separate reagents that must be added sequentially to the water sample.
- Sulfamic acid powder: the first reagent added to the water sample.
- HI736IND-0 phosphorus indicator reagent: the second reagent, added after the sulfamic acid powder has completely dissolved.
This change is related to chemical safety regulations and packaging requirements. The two reagents are therefore supplied in separate packaging.
The kit still contains enough reagents for 25 complete tests. Each measurement requires one sachet of sulfamic acid powder and one sachet of HI736IND-0 phosphorus indicator reagent.
Instructions for Using the Updated HI736-25 Reagents
First, complete the sample preparation and zero measurement according to the instructions supplied with your Hanna HI736 Checker. Then follow the steps below to add the updated reagents.
- Remove the cuvette from the Checker and unscrew the cap.
- Add one sachet of sulfamic acid powder to the water sample.
- Replace the cap and shake gently until the powder has dissolved.
- Unscrew the cap again.
- Add one sachet of HI736IND-0 phosphorus indicator reagent.
- Replace the cap and shake gently for 2 minutes until the powder has completely dissolved.
- Continue with the remaining measurement steps and reaction time as described in the HI736 Checker instructions.
Alternative: the original HI736-0 Phosphorus Ultra Low Range reagent may be used instead of the two separate reagents, following its corresponding instructions.
Why Measure Phosphorus in a Reef Aquarium?
Phosphorus is an important nutrient in aquarium water and is directly related to phosphate levels. Both excessively high and extremely low phosphate concentrations can affect coral growth, coloration and overall health.
The Hanna HI736 Checker measures phosphorus at very low concentrations, making it particularly suitable for reef aquariums where precise nutrient monitoring is essential.
Converting Phosphorus to Phosphate
The Hanna HI736 measures phosphorus (P) in µg/L (ppb), rather than measuring phosphate (PO4) directly.
To convert the measured phosphorus concentration into phosphate in mg/L (ppm), use the following formula:
Phosphate (mg/L) = Phosphorus (µg/L) × 3.066 ÷ 1000
For example, a reading of 10 µg/L phosphorus corresponds to approximately 0.031 mg/L phosphate.
Technical Specifications
| Brand | Hanna Instruments |
| Product Code | HI736-25 |
| Product | Phosphorus ULR Replacement Reagents |
| Number of Tests | 25 complete measurements |
| Measured Parameter | Phosphorus (P) |
| Measurement Range | 0–200 µg/L (ppb) |
| Compatible Instrument | Hanna HI736 Phosphorus ULR Checker |
| Reagents | Sulfamic acid powder and HI736IND-0 phosphorus indicator |
| Packaging | Two separate reagents per measurement |
Key Features
- Original Hanna Instruments replacement reagents
- Designed for the Hanna HI736 Phosphorus ULR Checker
- Updated formulation with two separate reagents
- 25 complete phosphorus tests per kit
- Measurement range of 0 to 200 µg/L phosphorus
- Ideal for precise nutrient monitoring in reef aquariums
- Easy to use with the updated instructions
With the Hanna HI736-25 Phosphorus ULR Reagents, you can continue to accurately monitor phosphorus levels in your aquarium water. The updated packaging contains two separate reagents per measurement while still providing 25 complete tests with your existing Hanna HI736 Checker.
Brand
-
-
Hanna
View 136 other products
Shipment
-
Above € 50,- free delivery in NL & BEIn stock Ordered before 16:00, shipped today *
Characteristic(s)
HI736-25 Reagents for phosphorus ULR, 0 to 200 μg / l, 25 pieces
Hanna
Ocean Store
Ocean Store is a modern webshop with a large selection of reef aquarium equipment, supplements and food for your (marine) aquarium. We excel in reachability, service and speed. Not only in delivery of your ordered goods, but also in the adequate answering of your (marine) aquarium related questions. We are happy to share our passion for reef aquariums with you!
Open: Available Monday / Friday 9:00-20:00
Phone: +31(0)78-6456669
€ 0.99 - € 2999.99
EUR
479190
Microbe-Lift Nite-Out II
M-NITEH04
Dupla-eeze Calanus Powder, 60 g
HO-81703
Hanna Reagents Phosphate 25pcs.
HI-713-25
Rio telescopic fishing net
Rio-telfn-3